Single screw pump instructions
Source: | Author:Momo | Published time: 2021-09-13 | 321 Views | Share:

G type of single screw pump is a new type of fluid conveying machinery and equipment, is widely used in the transmission of all kinds of media industries constant pressure continuous line, no pulsation, medium conveying without damage by adjusting the rotational speed change flow to flow to achieve the purpose of measuring, suction ability, work, low noise, no heating, inhaled can good, stable pressure and flow rate.In order to make the G type single screw pump in use without failure, increase its service life, Brith gives you a summary of some G type screw pump in use need to pay attention to the matters.


1, G type screw pump before boot, need to determine the direction of the screw pump operation, can not be reversed.


2, G type screw pump is strictly prohibited in the pump cavity without liquid under the condition of empty operation, must be started before the pump inlet liquid into the pump body after the start of the screw pump, so as to avoid idling wear of the screw pump stator.


3, newly installed or a long time to stop the pump several days after the screw pump, can not immediately start, should be injected into the pump body the right amount of lubricant or screw pump liquid, and then use the pipe tongs to pull a few turns before starting.


4, G type screw pump conveying high viscosity or containing particles and corrosive media, should be washed with water or solution cavity of the screw pump, prevent blocking, so as not to cause the next start screw pump difficult and damage the stator.


5, the use of single screw pump in winter when the temperature is low and not used should be excluded from the pump body fluid, to prevent the pump body frostbite or ice in the pump the next start to pull the bad stator.


6, G type screw pump in the process of using the bearing box should be regularly added lubricating oil, found that the shaft end has seepage, to timely treatment or replace the oil seal.


7, in the G screw pump operation such as abnormal circumstances, should immediately stop to check the reason, troubleshooting.

 