Electric heating mixing tank is composed of tank body, tank cover, sandwich, stirrer, electric heating tube, control box, etc.Electric heating mixing tank is installed on the sandwich electric heating pipe, through the sandwich into the heat conduction medium, so that the heating medium heated to the required temperature, the mixing tank as a whole for heating.In the production, electric heating mixing tank electric heating tube if the use of improper, may lead to the phenomenon of leakage, then, in the occurrence of electric heating mixing tank electric heating tube leakage phenomenon, how should be dealt with?The following Xiaobian to tell you about.
How should we check when the electric heating mixing tank leaks:
1. Whether the insulation at the outlet end of the electric heating pipe (wiring insulation and magnesium oxide powder insulation) is damaged.
2. Whether the surface of the electric heating pipe is damaged because of improper use.
3. Whether the wiring of the electric heating pipe is in contact with liquid or other conductive medium.
4, the circuit leads fall off and contact with the carrier.
5, whether the electric heating pipe power supply part is caused by pollution and leakage.
6, the high power electric heating pipe is not effectively grounded.
The electric heating pipe has burned out.
We should do a good job in the prevention of mixing tank treatment measures before leakage:
1, check the insulation treatment problem, if it is the wiring insulation treatment can do some repair, after the repair is invalid, it is recommended to replace the electric heating pipe.
2, if the water quality is poor, a lot of scale lead to breakdown, it is recommended to treat the water quality, can also be placed in the water tank magnesium rod;If it is caused by dry burning out of the water level, it is recommended to modify the design to ensure the normal use and safety of the electric heating pipe.
3, quickly clean the damp parts, dry treatment, conditions can be put into the oven for drying.
4, check the off of the wire, welding.
5. Clean and dry the contaminated parts.
6, high power electric heating pipe in use, and there are safety risks of leakage, so it is necessary to do a good job of grounding treatment.
7. If it is determined that the electric heating pipe has been burned out, it is recommended to replace the electric heating pipe with a new one.